Match Color, Application and Certification Documents
Color becomes more useful when it leads to the right technical documents. ForeverSeal's water, fuel-gas and oxygen ranges should be evaluated through different evidence routes; the document must match the product supplied.
| Color and series | Application | Documents to request | Regional or scope check |
|---|
| White: Aqua / Aqua Pro | Drinking-water and water-system selection | WRAS approval and ACS-related drinking-water documentation | WRAS for UK water-contact assessment; confirm the exact documentation accepted for a French or other destination-market project |
| Yellow: GasSafe / GasSafe Pro | Natural gas, LPG and relevant fuel-gas installations | UL, AGA and DVGW documentation, as required | Check the specified listing for North American projects, AGA for relevant Australian requirements, and DVGW for relevant German/European project requirements; local acceptance still governs |
| Green: UltraGas | Oxygen and high-purity gas selection | Applicable BAM oxygen test report | Check the tested product, sample/batch and conditions; not a blanket approval for every oxygen system |
White Aqua: Drinking-Water Evidence
For drinking-water enquiries, ask about the WRAS and ACS-related documents applicable to the ordered Aqua model. The supplied WRAS 2212523 identifies DF201 white extruded PTFE tape, with water contact up to 85°C. It concerns effects on water quality, not the mechanical pressure rating of a pipe joint.
The supplied ACS-related file is a Eurofins formulation positive-list conformity document, 26 CLP NY044, for natural-colored PTFE tape. Its stated scope must be distinguished from a blanket ACS approval for every finished product. Confirm the destination-market requirement and written correspondence between the certificate product identifier and the ordered Aqua SKU.
Yellow GasSafe: Select Documents for the Destination Market
For North American specifications, request the applicable UL listing and covered product details; do not describe a listing as universal legal acceptance. For relevant Australian projects, request the AGA certificate and covered models. For relevant German or European project specifications, review the DVGW certificate and applicable EN 751-3 scope. These are different evidence routes, not interchangeable regional labels.
The supplied records include UL file MH48783, AGA certificate 9389 identifying FS12 / FS19 / FS25, and DVGW certificates NG-5143DP0202 / 0203 identifying specified tape constructions. Check the exact GasSafe order against those identifiers and the full pressure, temperature, size and service conditions. Do not select the highest number from different documents to create a combined rating.
Green UltraGas: BAM Evidence for Oxygen Selection
For oxygen enquiries, request the applicable BAM test report and confirmation that it represents the selected UltraGas product and intended service. BAM evidence concerns the material tested under stated conditions; a sample test report is not continuing certification of the entire range.
The supplied BAM report concerns a specific sample and batch. Detailed results or extracts are not reproduced here. Confirm cleanliness, handling, operating conditions and the complete system's oxygen compatibility alongside the report. Green color and a BAM reference alone do not qualify every installation.